Publication: 0000-00-00 00:00:00
United States SAM

Oil Circuit Breaker Replacement at Laurel River Dam

Process Number W912P522S0001

USA

Dates:


Notice ID:

W912P522S0001

Department/Ind. Agency:

DEPT OF DEFENSE

Sub-tier:

DEPT OF DEFENSE

Sub Command:

US ARMY ENGINEER DISTRICT NASHVILLE

Office:

US ARMY ENGINEER DISTRICT NASHVILLE

General Information:


All Dates/Times are:

(utc-06:00) central standard time, chicago, usa

Updated Published Date:

nov 17, 2021 12:33 pm cst

Original Published Date:

0000-00-00 00:00:00

Updated Response Date:

nov 30, 2021 03:00 pm cst

Original Response Date:

nov 19, 2021 03:00 pm cst

Inactive Policy:

15 days after response date

Updated Inactive Date:

dec 15, 2021

Original Inactive Date:

dec 04, 2021

Initiative:
  • None***--***

Classification:


NAICS Code:

237130 - power and communication line and related structures construction

Description:


Original Set Aside:

The Government is issuing this Sources Sought Notice to determine a competitive basis. This is not a solicitation. No reimbursement will be made for any costs associated with providing information in response to this survey. This questionnaire is for market research purposes only. Only contractors capable of performing this type of work should respond to this notice. Requirement The U.S. Army Corps of Engineers (USACE), Nashville District, anticipates soliciting a requirement for a firm fixed price construction contract to remove three (3) existing oil circuit breakers and to provide and install three new modern day SF6 vacuum breakers at Laurel River Dam.The oil circuit breakers are rated at 161KV of maximum voltage and 1200 AMP of continuous current. Each breaker holds 1,900 gallons of oil. The estimated magnitude of this project is between $1,000,000 and $5,000,000. The types of work and skill sets for this requirement are as follows: a) Removal of existing equipment. b) Installation of three (3) new SF6 circuit breakers and associated control cables. c) Modification to direct operator controls or additions, where required. The anticipated NAICS code is 237130, Power and Communication Line and RelatedStructures Construction with a small business size standard of $39.5 million in average annual receipts. Survey The Government is issuing this notice to determine a competitive basis. This is not a solicitation and the items listed herein are subject to change or eliminated from the requirement. This questionnaire is for market research purposes only. Only contractors capable of performing this type of work should respond to this notice. Your response to this survey is requested by Friday, November 19, 2021 at 9:00 a.m. Central Time. All information MUST be submitted by e-mail to Contract Specialist Kristal Jones at Kristal.R.Jones@usace.army.mil. 1. Name of your firm: 2. CAGE: 3. Point of Contact, Phone number and EMAIL address: 4. Please list no more than three (3) projects which include the above referenced type of work. If possible, provide projects that cover the most skill sets listed above. Examples must be from projects in which your firm was the prime, or sub-contractor, and in which your firm performed at least 50% of the construction work. Examples must have been completed within the last eight (8) years. a. Project Name: Contract Number (if applicable): Year Completed: Prime Contractor or Sub-Contractor: Type and percentage of work self-performed (based on contract value): Dollar Amount: Cable Voltage: General Description of project: b. Project Name: Contract Number (if applicable): Year Completed: Prime Contractor or Sub-Contractor: Type and percentage of work self-performed (based on contract value): Dollar Amount: Cable Voltage: General Description of project: c. Project Name: Contract Number (if applicable): Year Completed: Prime Contractor or Sub-Contractor: Type and percentage of work self-performed (based on contract value): Dollar Amount: Cable Voltage: General Description of project: 5. Are you a Small Business classified under the above NAICS code? If so, do you fall into a sub-category (e.g. HubZone, 8(a), SDVOSB, WOSB, etc.)? 6. If your company is a small business concern, per FAR 52.219-14, at least 25 percent of the cost of contract performance incurred for personnel shall be expended for employees of the concern. Can your firm be expected to do this, given your current employee situation? (Please respond yes or no.) 7. If this requirement is advertised, do you anticipate submitting a proposal? 8. Please provide any additional information you feel is necessary. --15 November 2021: Amendment to the sources to notice to provide information regarding the voltage of the breakers and the amount of oil each breaker holds. The due date for responses has been extended to 30 November 2021 at 3:00 p.m. Central Time. --17 November 2021: Amendment to the sources sought notice to change the NAICS code from 238210 to 237130.

Attachments / Links:


Document Size Updated date Download

Contact Information:


KO CONTRACTING DIVISION 801 BROADWAY RM A604

NASHVILLE , TN 37203-1070

USA

Primary Point of Contacts:

Kristal R Jones