Pais / Región
Paises

Provincias / Departamentos
Colombia Colombia
Argentina Argentina
Canada Canada
Chile Chile
Ecuador Ecuador
España España
Guatemala Guatemala
Honduras Honduras
Mexico Mexico
Panama Panama
Paraguay Paraguay
United States United States
Uruguay Uruguay
Categorias / Industrias
Publication: 2021-10-22 07:43:00
United States SAM

THE PURPOSE OF AMENDMENT 0002 IS TO PROVIDE ADDITIONAL INFORMATION TO THE CONTRACTOR:

Process Number HC101322QA027

USA

Dates:


Notice ID:

HC101322QA027

Department/Ind. Agency:

DEPT OF DEFENSE

Sub-tier:

DEPT OF DEFENSE

Sub Command:

TELECOMMUNICATIONS DIVISION- HC1013

Office:

TELECOMMUNICATIONS DIVISION- HC1013

General Information:


All Dates/Times are:

(UTC-06:00) CENTRAL STANDARD TIME, CHICAGO, USA

Updated Published Date:

Nov 15, 2021 07:50 am CST

Original Published Date:

2021-10-22 07:43:00

Original Response Date:

Nov 22, 2021 04:00 pm CST

Inactive Policy:

Manual

Updated Inactive Date:

Nov 25, 2022

Original Inactive Date:

Nov 05, 2022

Initiative:
  • None***--***

Classification:


Original Set Aside:

Total Small Business Set-Aside (FAR 19.5)

Product Service Code:

DG11 - IT AND TELECOM IT AND TELECOM

NAICS Code:

517911 - Telecommunications Resellers

Description:


Original Set Aside:

THE PURPOSE OF AMENDMENT 0002 IS TO PROVIDE ADDITIONAL INFORMATION TO THE CONTRACTOR: 1. How long is the run from the DEMARC to the SDP? - 200-300 Ft inside wiring 2. Is there existing conduit to use? - No existing conduit could be found during walkthrough 3. Is any drilling through concrete or metal required? - potentially drilling might be necessary 4. Can drop celling’s be used? - Drop Celling is available and can be used 5. Can you provide the latitude and longitude of this address. - 39.124361, -75.469425 ***RECAP*** THE PURPOSE OF AMENDMENT 0001 IS TO REMOVE THE REQUIREMENTS LISTED BELOW: 1. LONG DISTANCE PIC CODE MUST BE 1010222. 2. ONCE LONG DISTANCE CARRIER IS ESTABLISHED, REQUEST PIK BLOCK BE PLACED ON THE LINE. 3. CALL BLOCK: ALL 700/900 AREA CODES 4. ALL OTHER LONG DISTANCE AND INTERNATIONAL DIALING IS TO BE UNHINDERED. 5. CALLER ID BE BLOCKED, LISTED AS UNAVAILABLE, OR MASKED. 6. NUMBER IS TO BE UNLISTED AND NON-PUBLISHED. 7. 3RD PARTY BLOCK IS TO BE ADDED TO THIS SERVICE. ALL ELSE REMAINS UNCHANGED AND THE STANDARD PROVISIONS CAN BE FOUND ON THE ORIGINAL SOLICITATION POSTING. ***RECAP***SUBMIT A QUOTE TO: 1. PROVIDE, INSTALL AND MAINTAIN AN INTERNET SERVICE WITH A MINIMUM OF 10 MEGABIT UP AND DOWNLOAD SPEEDS. 2. THE GOVERNMENT IS REQUESTING THE VENDOR (TECHNICIAN) TO INSTALL A NEW LINE (JACK) FROM THE NETWORK INTERFACE DEVICE (NID) TO THE USER LOCATION. THIS WILL ASSURE THAT THIS NEW SERVICE WILL NOT AFFECT ANY CURRENT SERVICES AT THE LOCATION. 3. TSP IS ALSO BEING ESTABLISHED FOR THIS CIRCUIT. 4. VENDOR MUST SCHEDULE ANY INITIAL WALKTHROUGH IF NEEDED 2 WEEKS PRIOR TO VISIT. 5. LONG DISTANCE PIC CODE MUST BE 1010222 6. ONCE LONG DISTANCE CARRIER IS ESTABLISHED, REQUEST PIK BLOCK BE PLACED ON THE LINE. 7. CALL BLOCK: ALL 700/900 AREA CODES 8. ALL OTHER LONG DISTANCE AND INTERNATIONAL DIALING IS TO BE UNHINDERED. 9. CALLER ID BE BLOCKED, LISTED AS UNAVAILABLE, OR MASKED. 10. NUMBER IS TO BE UNLISTED AND NON-PUBLISHED. 11. 3RD PARTY BLOCK IS TO BE ADDED TO THIS SERVICE. 12. THE TELCO IS RESPONSIBLE FOR INSIDE WIRING AS REQUESTED BY THE POC. 13. IN THE EVENT OF SUSPECTED FRAUD OR MISUSE THE VENDOR IS TO KEEP THE SERVICE ACTIVE AND CONTACT THE DISA NOSC AT 202-757-6001 BEFORE ANY ACTION IS TAKEN AGAINST THE CIRCUIT. 14. THE FINAL AWARD VENDOR MUST RESPOND TO AN OUTAGE WITHIN 1 HOUR. ***REMARKS*** 1. CONTRACTOR MUST CONTACT THE SITE POC(S) AT LEAST 72 HRS PRIOR TO INSTALLATION. 2. CONTRACTOR MUST CALL DISA NOSC 202-757-6001 AT LEAST 72 HRS PRIOR TO MAINTENANCE. 3. CUSTOMER WILL ACCEPT EARLIEST POSSIBLE INSTALL DATE. (SIP) 4. THIS IS A CANDIDATE FOR RESTORAL TELECOMMUNICATIONS SERVICE PRIORITY (TSP). ***NOTE: THE CONTRACTOR MUST PROVIDE TSR, CCSD OR CSA IN ALL CORRESPONDENCE INCLUDING WHEN DELIVERING CIRCUIT TO SITE POC*** TECHNICAL ACCEPTABILITY EVALUATION CRITERIA: A QUOTE MUST COMPLY WITH ALL STANDARD PROVISIONS, PROVISIONS, CLAUSES, AND ADDRESS SECTIONS F-M OF THE SOLICITATION TO BE DEEMED TECHNICALLY ACCEPTABLE. ALL PORTIONS OF THE SOLICITATION SHOULD BE CAREFULLY REVIEWED FOR ALL MANDATED REQUIREMENTS OUTLINED WITHIN THE STANDARD PROVISIONS AND DOCUMENTATION REQUESTED AS FOUND IN SECTION M AND AFFILIATED ATTACHMENTS. QUOTATIONS MUST INCLUDE ALL REQUIRED DOCUMENTS AND RESPONSES INDICATED FROM THESE STANDARD PROVISIONS, PROVISIONS, CLAUSES, SECTION M, AND AFFILIATED ATTACHMENTS TO BE CONSIDERED TECHNICALLY ACCEPTABLE AND/OR ELIGIBLE FOR AWARD. IN RESPONSE TO THIS IQO SOLICITATION, NO TERMS, CONDITIONS, OR ASSUMPTIONS WILL BE ENTERTAINED. IF TERMS, CONDITIONS, AND/OR ASSUMPTIONS ARE INCLUDED IN A QUOTATION, THE QUOTATION MAY BE EXCLUDED ON GROUNDS THAT IT FAILED TO COMPLY WITH THE IQO SOLICITATION INSTRUCTIONS. EVALUATION CRITERIA: IN ADDITION TO THE PROCEDURES OUTLINED IN STANDARD PROVISION 23, TECHNICAL EVALUATION TEAM MEMBERS WILL INCLUDE GOVERNMENT PERSONNEL AND MAY INCLUDE GOVERNMENT'S CONTRACTED ADVISORS. GOVERNMENT PERSONNEL WILL MAKE THE FINAL DETERMINATION OF TECHNICAL ACCEPTABILITY. IF THERE ARE QUESTIONS REGARDING SITE SURVEYS OR SITE INFORMATION PLEASE CONTACT THE CONTRACT SPECIALIST LISTED ON THIS SOLICITATION PRIOR TO THE QUOTE DUE DATE.

Attachments / Links:


Document Size Updated date Download

Contact Information:


2300 EAST DRIVE BUILDING 3600

SCOTT AFB , IL 622255406

USA

Primary Point of Contacts:

George Butler

Secondary Point of Contact:

Amanda Romanitis